Allow higher capture speed for 5 to 16 channels in Logic Pro 16

With the Logic 16, we could capture up to 3 channels at 100MS/s, then up to 6 at 50MS/s, then 7 at 40MS/s, 8 at 32MS/s, etc...
With the Logic Pro 16, the max capture speed is either 500MS/s for up to 4 channels or 100MS/s for 5 to 16 channels.
If the data from 16 channels at 100MS/s can be captured and transferred on the USB 3.0 connection, then surely we can capture at more than 100MS/s if we are only using 6 or 8 channels for example.
Being able to capture at 250MS/s or 200MS/s for 5 to 8 channels would be very useful.

  • Avatar32.5fb70cce7410889e661286fd7f1897de Guest
  • Jun 26 2018
  • Shipped
  • Attach files
  • Avatar40.8f183f721a2c86cd98fddbbe6dc46ec9
    Guest commented
    26 Jun 19:11

    This is the main reason I have not upgraded my Logic 16 to a Logic 16 Pro.