Show waves before the trigger for a configurable time

Sometimes it's very easy to set a trigger where an error is detected in firmware. However, what has happened just before the error is usually what you need to know for debugging! It would be very nice if I can say "trigger on X, and show the waves starting from Y seconds (or milliseconds) before X happened."

  • Avatar32.5fb70cce7410889e661286fd7f1897de Guest
  • Jun 26 2018
  • Shipped
  • Jun 26, 2018

    Admin Response

    Please see Options->Preferences; Pre-trigger buffer.
  • Attach files
  • Avatar40.8f183f721a2c86cd98fddbbe6dc46ec9
    Guest commented
    26 Jun 18:48

    It would be grateful if the trigger occured and then measurements stops.
    The presetted time will be shown as history from the past to the trigger.
    So it will not be neccessary to hit the stop button.

  • Avatar40.8f183f721a2c86cd98fddbbe6dc46ec9
    Guest commented
    26 Jun 18:48

    It is already possible:
    Go to "Options -> Preferences -> Capture" and set the "Pre-trigger buffer size" to a value like X-Y (e.g. = 5 seconds) in your example. Than you trigger at point X and can see the wave 5 seconds in front of trigger point X. It is independent from the "Duration (Recorde data for)" .... seconds.